Personal tools

Difference between revisions of "Channel type"

From PhotoVoltaic Logger new generation

Jump to: navigation, search
m
m
 
(7 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{TOCright}}
+
[[Category:Channel]]{{TOCright}}
== Direct channel types ==
+
== Direct ==
 +
 
 +
* '''Can't''' have child channels
 +
* '''Always''' readable
 +
* '''Always''' writable
 +
* Can '''always''' be used for charts
 +
 
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
! Channel type !! Model !! Example unit !! Childs !! Readable !! Writable !! Chart available
+
! Channel type !! Model !! Example unit
 
|-
 
|-
| Current sensor || Sensor || A || 0 || yes || yes || yes
+
| Current sensor || Sensor || A
 
|-
 
|-
| "Energy meter, absolute" || Meter || Wh || 0 || yes || yes || yes
+
| Energy meter, absolute || Meter || Wh
 
|-
 
|-
| Frequency sensor || Sensor || Hz || 0 || yes || yes || yes
+
| Frequency sensor || Sensor || Hz
 
|-
 
|-
| Gas meter || Meter || m³ || 0 || yes || yes || yes
+
| Gas meter || Meter || m³
 
|-
 
|-
| Gas sensor || Sensor || m³/h || 0 || yes || yes || yes
+
| Gas sensor || Sensor || m³/h
 
|-
 
|-
| Heat sensor || Sensor || W || 0 || yes || yes || yes
+
| Heat sensor || Sensor || W
 
|-
 
|-
| Humidity sensor || Sensor || % || 0 || yes || yes || yes
+
| Humidity sensor || Sensor || %
 
|-
 
|-
| Irradiation sensor || Sensor || W/m² || 0 || yes || yes || yes
+
| Irradiation sensor || Sensor || W/m²
 
|-
 
|-
| Luminosity sensor || Sensor || lm || 0 || yes || yes || yes
+
| Luminosity sensor || Sensor || lm
 
|-
 
|-
| Power sensor || Sensor || W || 0 || yes || yes || yes
+
| Power sensor || Sensor || W
 
|-
 
|-
| Power sensor counter || Counter || W || 0 || yes || yes || yes
+
| Power sensor counter || Counter || W
 
|-
 
|-
| Pressure sensor || Sensor || hPa || 0 || yes || yes || yes
+
| Pressure sensor || Sensor || hPa
 
|-
 
|-
| Radiation meter || Meter || µSV/h || 0 || yes || yes || yes
+
| Radiation meter || Meter || µSV/h
 
|-
 
|-
| Radiation sensor || Sensor || µSV || 0 || yes || yes || yes
+
| Radiation sensor || Sensor || µSV
 
|-
 
|-
| Rainfall meter || Meter || mm || 0 || yes || yes || yes
+
| Rainfall meter || Meter || mm
 
|-
 
|-
| Rainfall sensor || Sensor || mm/h || 0 || yes || yes || yes
+
| Rainfall sensor || Sensor || mm/h
 
|-
 
|-
| Switch || Switcher || || 0 || yes || yes || yes
+
| Switch || Switcher ||  
 
|-
 
|-
| Temperature sensor || Sensor || °C || 0 || yes || yes || yes
+
| Temperature sensor || Sensor || °C
 
|-
 
|-
| Timer || Meter || h || 0 || yes || yes || yes
+
| Timer || Meter || h
 
|-
 
|-
| Valve sensor || Sensor || ° || 0 || yes || yes || yes
+
| Valve sensor || Sensor || °
 
|-
 
|-
| Voltage sensor || Sensor || V || 0 || yes || yes || yes
+
| Voltage sensor || Sensor || V
 
|-
 
|-
| Water meter || Meter || m³ || 0 || yes || yes || yes
+
| Water meter || Meter || m³
 
|-
 
|-
| Water sensor || Sensor || m³/h || 0 || yes || yes || yes
+
| Water sensor || Sensor || m³/h
 
|-
 
|-
| Winddirection sensor || Sensor || ° || 0 || yes || yes || yes
+
| Winddirection sensor || Sensor || °
 
|-
 
|-
| Windspeed sensor || Sensor || m/s || 0 || yes || yes || yes
+
| Windspeed sensor || Sensor || m/s
 
|}
 
|}
  
== Internal calculated channel types ==
+
== Proxy ==
 +
 
 +
* '''Must''' have '''exact one''' child channel
 +
* '''Always''' readable
 +
* '''Never''' writable
 +
* Can '''always''' be used for charts
 +
 
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
! Channel type !! Model !! Example unit !! Childs !! Readable !! Writable !! Chart available
+
! Channel type !! Model !! Comment
 
|-
 
|-
| Daylight || Daylight || || none || yes || no || yes
+
| Baseline || Baseline ||
 
|-
 
|-
| Estimate || Estimate || Wh || none || yes || no || yes
+
| Calculator || Calculator ||
 
|-
 
|-
| Fixed value || Fix || || none || yes || no || yes
+
| Dashboard channel || Dashboard || (Should be used only in [[Dashboard module|dashboard]])
 
|-
 
|-
| Random || Random || || none || yes || no || yes
+
| History || History ||
 +
|-
 +
| Sensor to meter || SensorToMeter ||
 +
|-
 +
| Topline || Topline ||
 
|}
 
|}
  
== Proxy channels types ==
+
== Calculating ==
 +
 
 +
* '''Must''' have child channel(s)
 +
* '''Always''' readable
 +
* '''Never''' writable
 +
* Can '''always''' be used for charts
 +
 
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
! Channel type !! Model !! Example unit !! Childs !! Readable !! Writable !! Chart available
+
! Channel type !! Model !! Example unit !! Childs
 
|-
 
|-
| Baseline || Baseline ||  || 1 || yes || no || yes
+
| Accumulator || Accumulator ||  || unlimited
 
|-
 
|-
| Calculator || Calculator ||  || 1 || yes || no || yes
+
| Average || Average ||  || unlimited
 
|-
 
|-
| Dashboard channel || Dashboard ||  || 1 || yes || no || yes
+
| Differentiator || Differentiator ||  || unlimited
 
|-
 
|-
| History || History ||  || 1 || yes || no || yes
+
| Full Differentiator || DifferentiatorFull ||  || unlimited
 
|-
 
|-
| Sensor to meter || SensorToMeter ||  || 1 || yes || no || yes
+
| Import / Export || InternalConsumption ||  || 2
 
|-
 
|-
| Topline || Topline || || 1 || yes || no || yes
+
| Ratio calculator || Ratio || % || 2
 
|}
 
|}
  
== Calculating channels types ==
+
== General grouping ==
 +
 
 +
* '''Must''' have child channel(s), <tt>'''1 .. n'''</tt>
 +
* '''Never''' readable
 +
* '''Never''' writable
 +
* Can't '''never''' be used for charts
 +
 
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
! Channel type !! Model !! Example unit !! Childs !! Readable !! Writable !! Chart available
+
! Channel type !! Model
 
|-
 
|-
| Accumulator || Accumulator ||  || unlimited || yes || no || yes
+
| Building || Group
 
|-
 
|-
| Average || Average ||  || unlimited || yes || no || yes
+
| Group || Group
 
|-
 
|-
| Differentiator || Differentiator ||  || unlimited || yes || no || yes
+
| Inverter || Group
 
|-
 
|-
| Full Differentiator || DifferentiatorFull ||  || unlimited || yes || no || yes
+
| Multi-Sensor || Group
 
|-
 
|-
| Import / Export || InternalConsumption ||  || 2 || yes || no || yes
+
| Power plant || Group
|-
+
|}
| Ratio calculator || Ratio || % || 2 || yes || no || yes
+
 
 +
== Internal calculated ==
 +
 
 +
* '''Can't''' have child channels
 +
* '''Always''' readable
 +
* '''Never''' writable
 +
* Can '''always''' be used for charts
 +
 
 +
 
 +
{| class="wikitable"
 
|-
 
|-
| Fronius Inverter || Fronius\SolarNet ||  || unlimited || no || yes || no
+
! Channel type !! Model !! Example unit
 
|-
 
|-
| Fronius Sensorbox || Fronius\SolarNet || || unlimited || no || yes || no
+
| Daylight || Daylight ||
 
|-
 
|-
| OpenWeatherMap || JSON || || unlimited || no || yes || no
+
| Estimate || Estimate || Wh
 
|-
 
|-
| SMA Inverter || SMA\Webbox || || unlimited || no || yes || no
+
| Fixed value || Fix ||
 
|-
 
|-
| SMA Sensorbox || SMA\Webbox || || unlimited || no || yes || no
+
| Random || Random ||
|-
 
| SMA Sunny Webbox || SMA\Webbox ||  || unlimited || no || yes || no
 
|-
 
| Wunderground || JSON ||  || unlimited || no || yes || no
 
 
|}
 
|}
  
== General grouping channels types ==
+
== Specials ==
 +
 
 +
=== Collectors ===
 +
 
 +
These channel types accept special inputs for their readings.
 +
 
 +
* '''Must''' have child channel(s)
 +
* '''Never''' readable
 +
* '''Always''' writable
 +
* Can't '''never''' be used for charts
 +
 
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
! Channel type !! Model !! Example unit !! Childs !! Readable !! Writable !! Chart available
+
! Channel type !! Model !! Childs
 +
|-
 +
| Fronius Inverter || Fronius\SolarNet || unlimited
 
|-
 
|-
| Building || Group ||  || unlimited || no || no || no
+
| Fronius Sensorbox || Fronius\SolarNet || unlimited
 
|-
 
|-
| Group || Group ||  || unlimited || no || no || no
+
| OpenWeatherMap || JSON || unlimited
 
|-
 
|-
| Inverter || Group ||  || unlimited || no || no || no
+
| SMA Inverter || SMA\Webbox || unlimited
 
|-
 
|-
| Multi-Sensor || Group ||  || unlimited || no || no || no
+
| SMA Sensorbox || SMA\Webbox || unlimited
 
|-
 
|-
| Power plant || Group ||  || unlimited || no || no || no
+
| SMA Sunny Webbox || SMA\Webbox || unlimited
 
|-
 
|-
| Alias || Alias || || none || no || no || no
+
| Wunderground || JSON || unlimited
 
|}
 
|}
  
== Special channel types ==
+
=== Extractors ===
 +
 
 +
These channel types produces special outputs for their target usage.
 +
 
 +
* '''Must''' have child channel(s)
 +
* '''Always''' readable
 +
* '''Never''' writable
 +
* Can't '''never''' be used for charts
 +
 
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 153: Line 206:
 
| PV-Log Plant || PVLog\Plant || unlimited || yes || no || no
 
| PV-Log Plant || PVLog\Plant || unlimited || yes || no || no
 
|-
 
|-
| PV-Log Inverter (r2) || PVLog2\Inverter || unlimited || no || no || no
+
| PV-Log Inverter (r2) || PVLog2\Inverter || unlimited || no <small>(internally used by PV-Log Plant (r2))</small> || no || no
 
|-
 
|-
 
| PV-Log Plant (r2) || PVLog2\Plant || unlimited || yes || no || no
 
| PV-Log Plant (r2) || PVLog2\Plant || unlimited || yes || no || no

Latest revision as of 12:09, 19 April 2016

Direct

  • Can't have child channels
  • Always readable
  • Always writable
  • Can always be used for charts


Channel type Model Example unit
Current sensor Sensor A
Energy meter, absolute Meter Wh
Frequency sensor Sensor Hz
Gas meter Meter
Gas sensor Sensor m³/h
Heat sensor Sensor W
Humidity sensor Sensor  %
Irradiation sensor Sensor W/m²
Luminosity sensor Sensor lm
Power sensor Sensor W
Power sensor counter Counter W
Pressure sensor Sensor hPa
Radiation meter Meter µSV/h
Radiation sensor Sensor µSV
Rainfall meter Meter mm
Rainfall sensor Sensor mm/h
Switch Switcher
Temperature sensor Sensor °C
Timer Meter h
Valve sensor Sensor °
Voltage sensor Sensor V
Water meter Meter
Water sensor Sensor m³/h
Winddirection sensor Sensor °
Windspeed sensor Sensor m/s

Proxy

  • Must have exact one child channel
  • Always readable
  • Never writable
  • Can always be used for charts


Channel type Model Comment
Baseline Baseline
Calculator Calculator
Dashboard channel Dashboard (Should be used only in dashboard)
History History
Sensor to meter SensorToMeter
Topline Topline

Calculating

  • Must have child channel(s)
  • Always readable
  • Never writable
  • Can always be used for charts


Channel type Model Example unit Childs
Accumulator Accumulator unlimited
Average Average unlimited
Differentiator Differentiator unlimited
Full Differentiator DifferentiatorFull unlimited
Import / Export InternalConsumption 2
Ratio calculator Ratio  % 2

General grouping

  • Must have child channel(s), 1 .. n
  • Never readable
  • Never writable
  • Can't never be used for charts


Channel type Model
Building Group
Group Group
Inverter Group
Multi-Sensor Group
Power plant Group

Internal calculated

  • Can't have child channels
  • Always readable
  • Never writable
  • Can always be used for charts


Channel type Model Example unit
Daylight Daylight
Estimate Estimate Wh
Fixed value Fix
Random Random

Specials

Collectors

These channel types accept special inputs for their readings.

  • Must have child channel(s)
  • Never readable
  • Always writable
  • Can't never be used for charts


Channel type Model Childs
Fronius Inverter Fronius\SolarNet unlimited
Fronius Sensorbox Fronius\SolarNet unlimited
OpenWeatherMap JSON unlimited
SMA Inverter SMA\Webbox unlimited
SMA Sensorbox SMA\Webbox unlimited
SMA Sunny Webbox SMA\Webbox unlimited
Wunderground JSON unlimited

Extractors

These channel types produces special outputs for their target usage.

  • Must have child channel(s)
  • Always readable
  • Never writable
  • Can't never be used for charts


Channel type Model Childs Readable Writable Chart available
PV-Log Inverter PVLog\Inverter unlimited yes no no
PV-Log Plant PVLog\Plant unlimited yes no no
PV-Log Inverter (r2) PVLog2\Inverter unlimited no (internally used by PV-Log Plant (r2)) no no
PV-Log Plant (r2) PVLog2\Plant unlimited yes no no
Sonnenertrag JSON Sonnenertrag\JSON unlimited yes no no