Difference between revisions of "Kostal inverter"

From PhotoVoltaic Logger new generation

Jump to: navigation, search
m (Kostal inverter)
m
Line 3: Line 3:
 
For Kostal inverters is a template available.
 
For Kostal inverters is a template available.
  
To make sure, the definitions are correct please load 1st one data file from your inverter as [[Grouping models#Kostal|described here]]
+
To make sure, the definitions are correct please load 1<sup>st</sup> one data file from your inverter as [[Grouping models#Kostal|described here]]
  
 
This should look like this (TAB separated):
 
This should look like this (TAB separated):
  
  Logdaten
+
Logdaten
  Nr:    255
+
Nr:    255
  Name:    ZashPV10
+
Name:    ZashPV10
  akt. Zeit:    1470085218
+
akt. Zeit:    1470085218
 
+
  Logdaten U[V], I[mA], P[W], E[kWh], F[Hz], R[kOhm], Ain T[digit], Zeit[sec]
+
Logdaten U[V], I[mA], P[W], E[kWh], F[Hz], R[kOhm], Ain T[digit], Zeit[sec]
  Zeit        DC1 U    DC1 I    DC1 P    DC1 T    DC1 S    DC2 U    DC2 I    DC2 P    DC2 T    DC2 S  ...
+
Zeit        DC1 U    DC1 I    DC1 P    DC1 T    DC1 S    DC2 U    DC2 I    DC2 P    DC2 T    DC2 S  ...
  1469998800  496      10      5        44842    16393    274      17      4        44851    49162  ...
+
1469998800  496      10      5        44842    16393    274      17      4        44851    49162  ...
  
 
If you get this, create a complete inverter like this:
 
If you get this, create a complete inverter like this:
  
[[File:KostalExample1.png]]
 
  
Check on the next screen the assignment of the channels:
+
[[File:KostalExample0.png]]
  
[[File:KostalExample2.png]]
+
 
 +
[[File:KostalExample1.png|800px]]
 +
 
 +
 
 +
Review next the assignment of the channels if they match your data file.
 +
You can adjust here also all aspects of the single measuring data channels, e.g. names.
 +
 
 +
 
 +
[[File:KostalExample2.png|800px]]
 +
 
 +
 
 +
If have '''less than''' 3 MPP trackers, '''uncheck''' all the channels for the not existing trackers.
  
 
Check the GUID for the inverter channel and put this into the configuration in your scripts directory.
 
Check the GUID for the inverter channel and put this into the configuration in your scripts directory.

Revision as of 11:00, 5 August 2016

Kostal inverter

For Kostal inverters is a template available.

To make sure, the definitions are correct please load 1st one data file from your inverter as described here

This should look like this (TAB separated):

Logdaten
Nr:    255
Name:    ZashPV10
akt. Zeit:    1470085218

Logdaten U[V], I[mA], P[W], E[kWh], F[Hz], R[kOhm], Ain T[digit], Zeit[sec]
Zeit        DC1 U    DC1 I    DC1 P    DC1 T    DC1 S    DC2 U    DC2 I    DC2 P    DC2 T    DC2 S  ...
1469998800  496      10       5        44842    16393    274      17       4        44851    49162  ...

If you get this, create a complete inverter like this:


KostalExample0.png


KostalExample1.png


Review next the assignment of the channels if they match your data file. You can adjust here also all aspects of the single measuring data channels, e.g. names.


KostalExample2.png


If have less than 3 MPP trackers, uncheck all the channels for the not existing trackers.

Check the GUID for the inverter channel and put this into the configuration in your scripts directory.