Difference between revisions of "Kostal inverter"
From PhotoVoltaic Logger new generation
m (→Kostal inverter) |
m |
||
Line 3: | Line 3: | ||
For Kostal inverters is a template available. | For Kostal inverters is a template available. | ||
− | To make sure, the definitions are correct please load | + | To make sure, the definitions are correct please load 1<sup>st</sup> one data file from your inverter as [[Grouping models#Kostal|described here]] |
This should look like this (TAB separated): | This should look like this (TAB separated): | ||
− | + | Logdaten | |
− | + | Nr: 255 | |
− | + | Name: ZashPV10 | |
− | + | akt. Zeit: 1470085218 | |
− | + | ||
− | + | Logdaten U[V], I[mA], P[W], E[kWh], F[Hz], R[kOhm], Ain T[digit], Zeit[sec] | |
− | + | Zeit DC1 U DC1 I DC1 P DC1 T DC1 S DC2 U DC2 I DC2 P DC2 T DC2 S ... | |
− | + | 1469998800 496 10 5 44842 16393 274 17 4 44851 49162 ... | |
If you get this, create a complete inverter like this: | If you get this, create a complete inverter like this: | ||
− | |||
− | + | [[File:KostalExample0.png]] | |
− | [[File:KostalExample2.png]] | + | |
+ | [[File:KostalExample1.png|800px]] | ||
+ | |||
+ | |||
+ | Review next the assignment of the channels if they match your data file. | ||
+ | You can adjust here also all aspects of the single measuring data channels, e.g. names. | ||
+ | |||
+ | |||
+ | [[File:KostalExample2.png|800px]] | ||
+ | |||
+ | |||
+ | If have '''less than''' 3 MPP trackers, '''uncheck''' all the channels for the not existing trackers. | ||
Check the GUID for the inverter channel and put this into the configuration in your scripts directory. | Check the GUID for the inverter channel and put this into the configuration in your scripts directory. |
Revision as of 11:00, 5 August 2016
Kostal inverter
For Kostal inverters is a template available.
To make sure, the definitions are correct please load 1st one data file from your inverter as described here
This should look like this (TAB separated):
Logdaten Nr: 255 Name: ZashPV10 akt. Zeit: 1470085218 Logdaten U[V], I[mA], P[W], E[kWh], F[Hz], R[kOhm], Ain T[digit], Zeit[sec] Zeit DC1 U DC1 I DC1 P DC1 T DC1 S DC2 U DC2 I DC2 P DC2 T DC2 S ... 1469998800 496 10 5 44842 16393 274 17 4 44851 49162 ...
If you get this, create a complete inverter like this:
Review next the assignment of the channels if they match your data file.
You can adjust here also all aspects of the single measuring data channels, e.g. names.
If have less than 3 MPP trackers, uncheck all the channels for the not existing trackers.
Check the GUID for the inverter channel and put this into the configuration in your scripts directory.