Personal tools

Difference between revisions of "Channel type"

From PhotoVoltaic Logger new generation

Jump to: navigation, search
m
m
Line 2: Line 2:
 
== Direct ==
 
== Direct ==
  
* '''Can't have''' child channels
+
* '''Can't''' have child channels
* Always readable
+
* '''Always''' readable
* Always writable
+
* '''Always''' writable
* Can always be used for charts
+
* Can '''always''' be used for charts
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 64: Line 64:
 
== Proxy ==
 
== Proxy ==
  
* Must have '''exact one''' child channel
+
* '''Must''' have '''exact one''' child channel
* Always readable
+
* '''Always''' readable
* Never writable
+
* '''Never''' writable
* Can always be used for charts
+
* Can '''always''' be used for charts
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 88: Line 88:
 
== Calculating ==
 
== Calculating ==
  
* Must have child channel(s)
+
* '''Must''' have child channel(s)
* Always readable
+
* '''Always''' readable
* Never writable
+
* '''Never''' writable
* Can always be used for charts
+
* Can '''always''' be used for charts
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 112: Line 112:
 
== General grouping ==
 
== General grouping ==
  
* Must have child channel(s)
+
* '''Must''' have child channel(s)
* Never readable
+
* '''Never''' readable
* Never writable
+
* '''Never''' writable
* Can't never be used for charts
+
* Can't '''never''' be used for charts
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 134: Line 134:
 
== Internal calculated ==
 
== Internal calculated ==
  
* '''Can't have''' child channels
+
* '''Can't''' have child channels
* Always readable
+
* '''Always''' readable
* Never writable
+
* '''Never''' writable
* Can always be used for charts
+
* Can '''always''' be used for charts
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 152: Line 152:
 
|}
 
|}
  
== Special collectors ==
+
== Specials ==
 +
 
 +
=== Collectors ===
  
 
These channel types accept special inputs for their readings.
 
These channel types accept special inputs for their readings.
  
 
* '''Must''' have child channel(s)
 
* '''Must''' have child channel(s)
* Never readable
+
* '''Never''' readable
* Always writable
+
* '''Always''' writable
* Can't never be used for charts
+
* Can't '''never''' be used for charts
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 180: Line 182:
 
|}
 
|}
  
== Special extractors ==
+
=== Extractors ===
  
These channel types produces special outputs for their targets.
+
These channel types produces special outputs for their target usage.
  
 
* '''Must''' have child channel(s)
 
* '''Must''' have child channel(s)
* Always readable
+
* '''Always''' readable
* Never writable
+
* '''Never''' writable
* Can't never be used for charts
+
* Can't '''never''' be used for charts
  
 
{| class="wikitable"
 
{| class="wikitable"

Revision as of 10:05, 3 March 2014

Direct

  • Can't have child channels
  • Always readable
  • Always writable
  • Can always be used for charts
Channel type Model Example unit Readable Writable Chart available
Current sensor Sensor A yes yes yes
"Energy meter, absolute" Meter Wh yes yes yes
Frequency sensor Sensor Hz yes yes yes
Gas meter Meter yes yes yes
Gas sensor Sensor m³/h yes yes yes
Heat sensor Sensor W yes yes yes
Humidity sensor Sensor  % yes yes yes
Irradiation sensor Sensor W/m² yes yes yes
Luminosity sensor Sensor lm yes yes yes
Power sensor Sensor W yes yes yes
Power sensor counter Counter W yes yes yes
Pressure sensor Sensor hPa yes yes yes
Radiation meter Meter µSV/h yes yes yes
Radiation sensor Sensor µSV yes yes yes
Rainfall meter Meter mm yes yes yes
Rainfall sensor Sensor mm/h yes yes yes
Switch Switcher yes yes yes
Temperature sensor Sensor °C yes yes yes
Timer Meter h yes yes yes
Valve sensor Sensor ° yes yes yes
Voltage sensor Sensor V yes yes yes
Water meter Meter yes yes yes
Water sensor Sensor m³/h yes yes yes
Winddirection sensor Sensor ° yes yes yes
Windspeed sensor Sensor m/s yes yes yes

Proxy

  • Must have exact one child channel
  • Always readable
  • Never writable
  • Can always be used for charts
Channel type Model Childs Readable Writable Chart available
Baseline Baseline yes no yes
Calculator Calculator yes no yes
Dashboard channel Dashboard yes no yes (Should be used only in dashboard)
History History yes no yes
Sensor to meter SensorToMeter yes no yes
Topline Topline yes no yes

Calculating

  • Must have child channel(s)
  • Always readable
  • Never writable
  • Can always be used for charts
Channel type Model Example unit Childs Readable Writable Chart available
Accumulator Accumulator unlimited yes no yes
Average Average unlimited yes no yes
Differentiator Differentiator unlimited yes no yes
Full Differentiator DifferentiatorFull unlimited yes no yes
Import / Export InternalConsumption 2 yes no yes
Ratio calculator Ratio  % 2 yes no yes

General grouping

  • Must have child channel(s)
  • Never readable
  • Never writable
  • Can't never be used for charts
Channel type Model Childs Readable Writable Chart available
Building Group unlimited no no no
Group Group unlimited no no no
Inverter Group unlimited no no no
Multi-Sensor Group unlimited no no no
Power plant Group unlimited no no no

Internal calculated

  • Can't have child channels
  • Always readable
  • Never writable
  • Can always be used for charts
Channel type Model Example unit Childs Readable Writable Chart available
Daylight Daylight none yes no yes
Estimate Estimate Wh none yes no yes
Fixed value Fix none yes no yes
Random Random none yes no yes

Specials

Collectors

These channel types accept special inputs for their readings.

  • Must have child channel(s)
  • Never readable
  • Always writable
  • Can't never be used for charts
Channel type Model Childs Readable Writable Chart available
Fronius Inverter Fronius\SolarNet unlimited no yes no
Fronius Sensorbox Fronius\SolarNet unlimited no yes no
OpenWeatherMap JSON unlimited no yes no
SMA Inverter SMA\Webbox unlimited no yes no
SMA Sensorbox SMA\Webbox unlimited no yes no
SMA Sunny Webbox SMA\Webbox unlimited no yes no
Wunderground JSON unlimited no yes no

Extractors

These channel types produces special outputs for their target usage.

  • Must have child channel(s)
  • Always readable
  • Never writable
  • Can't never be used for charts
Channel type Model Childs Readable Writable Chart available
PV-Log Inverter PVLog\Inverter unlimited yes no no
PV-Log Plant PVLog\Plant unlimited yes no no
PV-Log Inverter (r2) PVLog2\Inverter unlimited no no no
PV-Log Plant (r2) PVLog2\Plant unlimited yes no no
Sonnenertrag JSON Sonnenertrag\JSON unlimited yes no no