Personal tools

S0 serial reader

From PhotoVoltaic Logger new generation

Revision as of 22:37, 22 March 2014 by KKoPV (talk | contribs) (Daemon)
Jump to: navigation, search

This is a part of the PVLng-scripts repository.

Scripts located in S0/

To read S0 impulses from e.g. energy meters, a program and a script to store this into PVLng is included.

Hardware requirements

Energy meter

You need a energy meter with S0 interface, best for 3 phases.

B-Watt.png

B-Watt Swissnox 3x5(80A)

Serial port adapter

If your computer not more have a serial port (like mine), you need a USB serial adapter.

The best choice is an adapter with a FTDI or a FT232RL chip set.

DigitusDA70156.png

Digitus DA-70156 USB to Serial Adapter, USB 2.0

During prototyping a gender changer (female/female) is recommended.

Connect your S0 port like this to your serial interface:

S0SerialPins.png

Or you recycle an old serial mouse cable...

S0SerialMouse.png

USB to TTL Serial Cable

I found also a bit cheaper possibility, a USB to TTL Adapter with 6 pins.

This cable is originally used for Arduino compatible boards but it works perfect also for S0 signals.

FTDI-FT232-USBtoTTL.jpg FTDI-FT232-USBtoTTL-2.jpg

Please note:

  • You need a cable with 6 pins, not only 4 pins, although we need only 2 of them!

Mostly I found these pin - wire associations:

Wire:   Red   Black   White   Green   Yellow   Blue
Signal: 5V GND RXD TXD RTS CTS

You can find them on eBay, shipping from China to Germany took abt. 3 weeks.

Test

adapted from Volkszähler Wiki

You should test your setup, to make sure, the signals will be correct detected. A simple test can be done with stty.

- Configure your device (50 Baud, return direct every character)

$ stty time 1 min 1 -icanon < /dev/ttyUSB0

- Read each character and create a timestamp:

$ strace -ttt -e read cat < /dev/ttyUSB0 > /dev/null

- With a bit more code you can better check the results

$ (strace -ttt -e read cat < /dev/ttyUSB0 > /dev/null) 2>&1 | \
  awk 'NR==1{t0=$1; next}{t=$1; print 3600e3 /(t-t1)/2000, t-t0, t-t1, $0; t1=t}'

Adjust the device and the 2000 to the impulse rate of your watt meter!

Result column Description
1 Power in watt
2 Current time in seconds
3 Time difference since last impulse
4 Original trace output with timestamp

Channel definition

Please put the device where your energy meter is connected to into the channel attribute like this:

S0PowerSensorChannel.png

It is strongly recommended to define a fixed name for your device!

Software

The software for storing the power data is splited into 2 parts

1. Daemon

An energy meter with S0 interface sends depending of the actual power usage an amount of impulses per kilo watt hour.

A common frequency is 1000 or 2000 per kilo watt hour, or 800 as for our energy meter.

The daemon runs in Background and detects these impulses. It converts them to power usage in watt.

These power values are written into log file.

2. Shell script

The shell script run each minute via cron, analyses the log file and calculates the average.

This average value will then pushed to the PVLng API.

Daemon

$ cd S0/bin
$ ./compile

Afterwards just test it to make sure all works fine.

Test

$ ./S0

Usage: bin/S0 -d <device> [options]

Options:

        -d <device>         Serial port device, required
        -r <resolution>     Impulses per kWh (kilo watt hour), default 1000
        -f <format>         Output format, must fit printf(), default "%f"
        -l <filename>       Log file, default /tmp/S0.log
        -v                  Verbosity level: info
        -vv                 Verbosity level: debug
        -F                  Don't daemonize, run in foreground
        -h                  Show this help

If program runs in foreground, measuring data are written to stdout instead of log file.

# Run for test very verbose in foreground
$ ./S0 -d /dev/usb-ftdi-1 -r 800 -Fvv
[22-Mar 22:35:18][-d ]  Device    : /dev/usb-ftdi-1
[22-Mar 22:35:18][-r ]  Resolution: 800
[22-Mar 22:35:18][-f ]  Format    : %f
[22-Mar 22:35:18][-l ]  Log file  : /tmp/S0.log
[22-Mar 22:35:18][-v ]  Verbosity : 2
[22-Mar 22:35:18][-F ]  Foreground: yes
[22-Mar 22:35:18]       Device /dev/usb-ftdi-1 opened
[22-Mar 22:35:18]       Start listening
[22-Mar 22:35:18]       Press Ctrl+C to abort ...
[22-Mar 22:35:18]       Skip 1st impulse
[22-Mar 22:35:23]       1395524123.582 - 976.773414
[22-Mar 22:35:28]       1395524128.188 - 976.974449
[22-Mar 22:35:32]       1395524132.802 - 975.276735
[22-Mar 22:35:37]       1395524137.393 - 980.170497
[22-Mar 22:35:41]       1395524141.984 - 980.166868
[22-Mar 22:35:46]       1395524146.588 - 977.398846
[22-Mar 22:35:51]       1395524151.210 - 973.802969
Ctrl+C

Script

Configuration

Please refer to S0.conf.dist to configure your environment regarding interfaces and channels.

$ cp S0.conf.dist S0.conf

Test

To test your configuration, run

$ ./S0.sh -tv S0.conf

Run with cron

Edit your crontab with

$ crontab -e

and add the following lines

# run S0 reader each minute
* * * * * /path/to/PVLng-sctipts/S0/S0.sh S0.conf